Skip to content
HUAJUNXINHarness

Selection guide

How to choose a wire harness

Four facts decide most harness orders: the interface, the wire gauge against the current, the protection rating and the terminal at the far end. This guide takes them in that order and points to the model pages whose listed values you can compare.

Start with four facts about your circuit

A wire harness is a cable with connectors moulded or crimped on, so choosing one is mostly a matching job. You match the connector to the mating part on your equipment, the conductor to the current it must carry, the sealing to the place it will sit, and the free end to whatever you are connecting it to. If you can answer those four points before you write to a supplier, the quotation usually comes back right the first time.

Everything below uses values that are printed on the model pages of this site. Where a page does not publish a number, the guide says so and the answer is to ask the sales team, not to assume. Prices, minimum quantities and delivery times are not part of any model page; they are given on the quotation.

  • Interface: the plug, socket or housing that mates with your battery, panel or device.
  • Gauge and current: the AWG of the wire, and the continuous and peak current of the circuit.
  • Protection: whether the joint must resist dust, splashes or temporary immersion.
  • Termination: bare tinned wire, ring terminal, clip, terminal block or a second connector.

Choose by interface

Interface comes first because it is the one choice you cannot adjust later. A battery with an XT90 socket needs an XT90 plug whatever the wire is. The catalogue groups its harnesses by interface family for that reason, and the table below lists the families with the values the model pages publish.

InterfaceExample modelListed current or voltageListed wire
XT60 plug and socketXT60 male and female with pigtail30A continuous, 60A peak; 500V DC14AWG silicone, 20cm standard
XT90 plug and socketXT90 male and female cable connector90A continuous12AWG silicone as standard, customisable
XT90L latch typeXT90L male and female90A continuous14AWG silicone, customisable
XT90NE-M panel mountXT90NE-M panel mount male90A continuous12AWG silicone, gauge replacement supported
EC5 with clipsCar emergency jump start cable12V; maximum peak 600ANot published on the page
SAE with ring terminalSAE cable with ring terminal and fuse holderDC 12V or 24V; 5A to 20A16, 18 or 20AWG
M12 aviation plugM12 straight male, 4 pinNot published on the pageShielded or unshielded cable
BMW-style headBMW male and female single-head line5V; 2A2464-28AWG

Values are quoted from each model page. A cell that says not published means the page has no figure; ask sales before you design around it.

Energy storage and battery harnesses

For energy storage cabinets, portable power stations and lithium packs, the usual choice is the XT family. The page for the XT60 pigtail lists 30A continuous and 60A peak, while the XT90 variants list 90A continuous. The XT90L adds a built-in lock buckle and an internal O-shaped sealing ring, and the XT90NE-M is built for panel mounting with fixed lugs on both sides. Choose the plain type for a cable-to-cable joint, the L type where vibration could loosen the plug, and the panel type where the connector sits in an enclosure wall.

The pages for these families are grouped on the XT60 and XT90 connector cables page, and the 2+4 interface battery cable is listed separately because its four signal pins beside the two power pins make it a different part.

Automotive and jump-start harnesses

Vehicle work splits into three jobs. Jump-start and clip leads use EC5 or alligator clips, fused power taps use SAE connectors or fuse holders, and under-bonnet sensor connections use sealed multi-core connector sets. The EC5 jump-start cables and SAE, fuse-holder and ring-terminal cables pages show the options. Fuse taps and holders list the fuse sizes they accept, so state the fuse you plan to fit when you ask for a quote.

Waterproof harnesses and aviation plugs

When the joint sits outdoors or under a vehicle, choose from the waterproof line. M8, M12 and GX12 aviation plugs are screw-locking round connectors; the M12 pages list IP65 as standard with IP67 optional, and the GX12 extension page lists lengths from 2 to 20 meters with 3, 4, 5, 6 or 8 cores. Compare them on the aviation plug family page.

BMW-style heads

The BMW-style single-head and male-to-female lines are low-power signal and supply cables: the pages list 5V and 2A with a fine 28AWG conductor. They are the wrong choice for a battery or motor circuit. Check the BMW connector cables family before assuming a head fits your socket, and send a photo of the mating part if the name is unclear.

Choose by wire gauge and current

AWG is an inverse scale: a smaller number means a thicker conductor. Thicker wire carries more current with less heating and less voltage drop, and it costs more and bends less easily. Length matters as well, because a long thin run loses more voltage than a short one. The harness is only as strong as its weakest part, which can be the connector, the wire or the fuse, so read the page for which element sets the limit.

The table pairs gauge with current for models that publish both. It is not a general ampacity chart. It shows what each listed model states, and where the page ties current to gauge, the table says so.

ModelListed gaugeListed currentNote on the page
XT60 with pigtail cable14AWG30A continuous, 60A peakPure power, no data
XT90 male and female12AWG standard90A continuousGauge customisable
Alligator clip to ring terminal12 to 14AWG10A to 30AHigher current through a heavier gauge on request
EC5 to alligator clip with fuse12, 14 or 16AWGPeak 100A to 200ASelectable by wire gauge; fuse 10A, 15A, 20A or 30A
SAE cable with fuse holder16, 18 or 20AWG5A to 20ADepends on gauge and fuse rating
Waterproof blade fuse holder harness12 to 22AWGMaximum 30ASubject to gauge and fuse rating
High-current battery connection cable10, 8, 6 or 4AWGNot published on the pageGauge chosen for the current requirement
BMW single-head line28AWG2A at 5VFine signal and supply cable

Peak and continuous are different figures. Where only a peak is listed, ask sales for the continuous value before you size a long-running load.

Three habits keep the choice safe. First, size to the continuous current, not to the peak that appears in the headline. Second, if the harness has a fuse, pick the fuse for the wire, not the wire for the fuse. Third, state the cable length with the current, because a heavier gauge may be wise on a long run even when the connector allows more. The temperature range on the page matters too: the silicone-sheathed battery cable lists -40℃ to 105℃, while the PVC option lists a narrower range.

Choose by waterproof rating

IP65 and IP67 are the two protection classes these pages list for sealed harnesses. The product pages describe IP67 as dustproof with protection against temporary immersion, and IP65 is the lower of the two. The rating applies to the connector in the state the page names: mated, locked or with the cover closed. An unmated plug should not be treated as an IP67 plug.

Rating on the pageModelCondition stated
IP67Automotive connector setsWhen mated; silicone ring plus rubber plug
IP67MC4 PV cableWhen the connector is locked
IP67M12 waterproof male and female cablesListed waterproof rating
IP65 standard, IP67 optionalM12 single-ended male aviation cableIntegrated injection moulding
IP65Waterproof blade fuse holder harnessWith the cover fully closed
IP54SAE cable with fuse holderWith dust and water cap installed
IP40Car fuse tapDry interior use

The XT90L page lists a built-in O-shaped sealing ring but no IP figure, so ask sales before you rely on it outdoors.

Waterproofing in these harnesses comes from construction, not from a label. The pages describe integrated injection moulding of the plug to the cable, silicone sealing rings, rubber plugs at the outlet end and heat-shrink tubing over joints. Choose the rating that matches the real exposure: a harness inside a dry cabinet is a different job from a camera lead under a truck. If you need documentation for the rating, ask the sales team what can be supplied for your model; do not assume it exists.

Choose by terminal type

The far end decides how fast the harness goes into your product. A bare tinned end suits soldering or a terminal block. A ring terminal bolts straight onto a battery post. A clip fits a temporary connection. A second connector gives you a plug-in cable-to-cable lead. The pages list these options as follows.

TerminationWhere it is listedDetail on the page
Stripped and tinned wire endsXT90, XT90L, XT90NE-M, M12 single-endedOptional process; pre-tinned as standard on the XT60 pigtail
Ring terminalHigh-current battery cable, SAE ring cableHole sizes 6mm, 8mm, 10mm; 12mm listed on the battery cable
Alligator clipsEC5 start cables, clip to ring terminalRed and black, colour-coded polarity
Pluggable terminal block and RJ45Network power Y-splitting harnessBranch lengths and wiring order adjustable
MC4 plugMC4 PV cablePlug at one end, stripped and tinned wires at the other

Hole size should match the bolt on your battery or busbar; send the bolt size with the request.

What to send when you ask for a custom harness

Most pages say that length, gauge, colour, termination and reinforcement can be changed. The quickest route to a correct quotation is to put the decisions above into one message. The inquiry form on this site has matching fields, and the custom harness page lists the options as the catalogue states them.

  • The model name or interface, or a photo and drawing of the mating part.
  • Voltage, continuous current and peak current in the circuit.
  • Wire gauge in AWG, or the gauge you want replaced, and the total length.
  • Termination at each end: bare tinned, ring terminal with hole size, clip, terminal block.
  • Protection need: dry, splash, outdoor or immersion, and whether the plug will be mated.
  • Sheath preference, colour, marking and packaging if they matter.
  • Quantity, destination country and a reference sample or drawing link if you have one.

Price, minimum order and delivery time are set on the quotation and depend on the model, so no figure is given here. Use the inquiry form to send the list in one go.

Frequently asked questions

Can a harness be made to my own length and wire gauge?

Most model pages say custom length and replacement gauges are available. Send the interface, the length and the gauge you want through the inquiry form, and the sales team will confirm what can be made for that model.

How do I check that the wire gauge is heavy enough?

Compare your continuous current and cable length with the gauge and current pair on the model page, and remember that the connector or the fuse may set the limit. If your load runs continuously or the cable is long, ask the sales team to confirm the gauge for your case.

How is waterproofing achieved, and is the rating a certificate?

The pages describe integrated injection moulding, silicone sealing rings, rubber plugs and heat-shrink joints. The IP figure is the protection class the model page lists, in the mated or closed state it names. If your project needs supporting paperwork, ask sales what is available for your model.

What is the difference between peak and continuous current?

Continuous current is what the harness can carry for as long as the load runs. Peak current is a short surge. The XT60 pigtail page lists both. Size the harness to the continuous figure.

Can I get a sample before an order?

Ask the sales team to confirm whether a sample is possible for your model and what it involves.

My connector is not listed. What should I send?

Send a photo of the mating part, any name or markings on it and the circuit voltage and current. The sales team can tell you whether a listed family fits or whether it needs a drawing.

Have the drawing or the interface list ready?

Request a quote