Selection guide
How to choose a wire harness
Four facts decide most harness orders: the interface, the wire gauge against the current, the protection rating and the terminal at the far end. This guide takes them in that order and points to the model pages whose listed values you can compare.
Start with four facts about your circuit
A wire harness is a cable with connectors moulded or crimped on, so choosing one is mostly a matching job. You match the connector to the mating part on your equipment, the conductor to the current it must carry, the sealing to the place it will sit, and the free end to whatever you are connecting it to. If you can answer those four points before you write to a supplier, the quotation usually comes back right the first time.
Everything below uses values that are printed on the model pages of this site. Where a page does not publish a number, the guide says so and the answer is to ask the sales team, not to assume. Prices, minimum quantities and delivery times are not part of any model page; they are given on the quotation.
- Interface: the plug, socket or housing that mates with your battery, panel or device.
- Gauge and current: the AWG of the wire, and the continuous and peak current of the circuit.
- Protection: whether the joint must resist dust, splashes or temporary immersion.
- Termination: bare tinned wire, ring terminal, clip, terminal block or a second connector.
Choose by interface
Interface comes first because it is the one choice you cannot adjust later. A battery with an XT90 socket needs an XT90 plug whatever the wire is. The catalogue groups its harnesses by interface family for that reason, and the table below lists the families with the values the model pages publish.
| Interface | Example model | Listed current or voltage | Listed wire |
|---|---|---|---|
| XT60 plug and socket | XT60 male and female with pigtail | 30A continuous, 60A peak; 500V DC | 14AWG silicone, 20cm standard |
| XT90 plug and socket | XT90 male and female cable connector | 90A continuous | 12AWG silicone as standard, customisable |
| XT90L latch type | XT90L male and female | 90A continuous | 14AWG silicone, customisable |
| XT90NE-M panel mount | XT90NE-M panel mount male | 90A continuous | 12AWG silicone, gauge replacement supported |
| EC5 with clips | Car emergency jump start cable | 12V; maximum peak 600A | Not published on the page |
| SAE with ring terminal | SAE cable with ring terminal and fuse holder | DC 12V or 24V; 5A to 20A | 16, 18 or 20AWG |
| M12 aviation plug | M12 straight male, 4 pin | Not published on the page | Shielded or unshielded cable |
| BMW-style head | BMW male and female single-head line | 5V; 2A | 2464-28AWG |
Values are quoted from each model page. A cell that says not published means the page has no figure; ask sales before you design around it.
Energy storage and battery harnesses
For energy storage cabinets, portable power stations and lithium packs, the usual choice is the XT family. The page for the XT60 pigtail lists 30A continuous and 60A peak, while the XT90 variants list 90A continuous. The XT90L adds a built-in lock buckle and an internal O-shaped sealing ring, and the XT90NE-M is built for panel mounting with fixed lugs on both sides. Choose the plain type for a cable-to-cable joint, the L type where vibration could loosen the plug, and the panel type where the connector sits in an enclosure wall.
The pages for these families are grouped on the XT60 and XT90 connector cables page, and the 2+4 interface battery cable is listed separately because its four signal pins beside the two power pins make it a different part.
Automotive and jump-start harnesses
Vehicle work splits into three jobs. Jump-start and clip leads use EC5 or alligator clips, fused power taps use SAE connectors or fuse holders, and under-bonnet sensor connections use sealed multi-core connector sets. The EC5 jump-start cables and SAE, fuse-holder and ring-terminal cables pages show the options. Fuse taps and holders list the fuse sizes they accept, so state the fuse you plan to fit when you ask for a quote.
Waterproof harnesses and aviation plugs
When the joint sits outdoors or under a vehicle, choose from the waterproof line. M8, M12 and GX12 aviation plugs are screw-locking round connectors; the M12 pages list IP65 as standard with IP67 optional, and the GX12 extension page lists lengths from 2 to 20 meters with 3, 4, 5, 6 or 8 cores. Compare them on the aviation plug family page.
BMW-style heads
The BMW-style single-head and male-to-female lines are low-power signal and supply cables: the pages list 5V and 2A with a fine 28AWG conductor. They are the wrong choice for a battery or motor circuit. Check the BMW connector cables family before assuming a head fits your socket, and send a photo of the mating part if the name is unclear.
Choose by wire gauge and current
AWG is an inverse scale: a smaller number means a thicker conductor. Thicker wire carries more current with less heating and less voltage drop, and it costs more and bends less easily. Length matters as well, because a long thin run loses more voltage than a short one. The harness is only as strong as its weakest part, which can be the connector, the wire or the fuse, so read the page for which element sets the limit.
The table pairs gauge with current for models that publish both. It is not a general ampacity chart. It shows what each listed model states, and where the page ties current to gauge, the table says so.
| Model | Listed gauge | Listed current | Note on the page |
|---|---|---|---|
| XT60 with pigtail cable | 14AWG | 30A continuous, 60A peak | Pure power, no data |
| XT90 male and female | 12AWG standard | 90A continuous | Gauge customisable |
| Alligator clip to ring terminal | 12 to 14AWG | 10A to 30A | Higher current through a heavier gauge on request |
| EC5 to alligator clip with fuse | 12, 14 or 16AWG | Peak 100A to 200A | Selectable by wire gauge; fuse 10A, 15A, 20A or 30A |
| SAE cable with fuse holder | 16, 18 or 20AWG | 5A to 20A | Depends on gauge and fuse rating |
| Waterproof blade fuse holder harness | 12 to 22AWG | Maximum 30A | Subject to gauge and fuse rating |
| High-current battery connection cable | 10, 8, 6 or 4AWG | Not published on the page | Gauge chosen for the current requirement |
| BMW single-head line | 28AWG | 2A at 5V | Fine signal and supply cable |
Peak and continuous are different figures. Where only a peak is listed, ask sales for the continuous value before you size a long-running load.
Three habits keep the choice safe. First, size to the continuous current, not to the peak that appears in the headline. Second, if the harness has a fuse, pick the fuse for the wire, not the wire for the fuse. Third, state the cable length with the current, because a heavier gauge may be wise on a long run even when the connector allows more. The temperature range on the page matters too: the silicone-sheathed battery cable lists -40℃ to 105℃, while the PVC option lists a narrower range.
Choose by waterproof rating
IP65 and IP67 are the two protection classes these pages list for sealed harnesses. The product pages describe IP67 as dustproof with protection against temporary immersion, and IP65 is the lower of the two. The rating applies to the connector in the state the page names: mated, locked or with the cover closed. An unmated plug should not be treated as an IP67 plug.
| Rating on the page | Model | Condition stated |
|---|---|---|
| IP67 | Automotive connector sets | When mated; silicone ring plus rubber plug |
| IP67 | MC4 PV cable | When the connector is locked |
| IP67 | M12 waterproof male and female cables | Listed waterproof rating |
| IP65 standard, IP67 optional | M12 single-ended male aviation cable | Integrated injection moulding |
| IP65 | Waterproof blade fuse holder harness | With the cover fully closed |
| IP54 | SAE cable with fuse holder | With dust and water cap installed |
| IP40 | Car fuse tap | Dry interior use |
The XT90L page lists a built-in O-shaped sealing ring but no IP figure, so ask sales before you rely on it outdoors.
Waterproofing in these harnesses comes from construction, not from a label. The pages describe integrated injection moulding of the plug to the cable, silicone sealing rings, rubber plugs at the outlet end and heat-shrink tubing over joints. Choose the rating that matches the real exposure: a harness inside a dry cabinet is a different job from a camera lead under a truck. If you need documentation for the rating, ask the sales team what can be supplied for your model; do not assume it exists.
Choose by terminal type
The far end decides how fast the harness goes into your product. A bare tinned end suits soldering or a terminal block. A ring terminal bolts straight onto a battery post. A clip fits a temporary connection. A second connector gives you a plug-in cable-to-cable lead. The pages list these options as follows.
| Termination | Where it is listed | Detail on the page |
|---|---|---|
| Stripped and tinned wire ends | XT90, XT90L, XT90NE-M, M12 single-ended | Optional process; pre-tinned as standard on the XT60 pigtail |
| Ring terminal | High-current battery cable, SAE ring cable | Hole sizes 6mm, 8mm, 10mm; 12mm listed on the battery cable |
| Alligator clips | EC5 start cables, clip to ring terminal | Red and black, colour-coded polarity |
| Pluggable terminal block and RJ45 | Network power Y-splitting harness | Branch lengths and wiring order adjustable |
| MC4 plug | MC4 PV cable | Plug at one end, stripped and tinned wires at the other |
Hole size should match the bolt on your battery or busbar; send the bolt size with the request.
What to send when you ask for a custom harness
Most pages say that length, gauge, colour, termination and reinforcement can be changed. The quickest route to a correct quotation is to put the decisions above into one message. The inquiry form on this site has matching fields, and the custom harness page lists the options as the catalogue states them.
- The model name or interface, or a photo and drawing of the mating part.
- Voltage, continuous current and peak current in the circuit.
- Wire gauge in AWG, or the gauge you want replaced, and the total length.
- Termination at each end: bare tinned, ring terminal with hole size, clip, terminal block.
- Protection need: dry, splash, outdoor or immersion, and whether the plug will be mated.
- Sheath preference, colour, marking and packaging if they matter.
- Quantity, destination country and a reference sample or drawing link if you have one.
Price, minimum order and delivery time are set on the quotation and depend on the model, so no figure is given here. Use the inquiry form to send the list in one go.
Frequently asked questions
Can a harness be made to my own length and wire gauge?
Most model pages say custom length and replacement gauges are available. Send the interface, the length and the gauge you want through the inquiry form, and the sales team will confirm what can be made for that model.
How do I check that the wire gauge is heavy enough?
Compare your continuous current and cable length with the gauge and current pair on the model page, and remember that the connector or the fuse may set the limit. If your load runs continuously or the cable is long, ask the sales team to confirm the gauge for your case.
How is waterproofing achieved, and is the rating a certificate?
The pages describe integrated injection moulding, silicone sealing rings, rubber plugs and heat-shrink joints. The IP figure is the protection class the model page lists, in the mated or closed state it names. If your project needs supporting paperwork, ask sales what is available for your model.
What is the difference between peak and continuous current?
Continuous current is what the harness can carry for as long as the load runs. Peak current is a short surge. The XT60 pigtail page lists both. Size the harness to the continuous figure.
Can I get a sample before an order?
Ask the sales team to confirm whether a sample is possible for your model and what it involves.
My connector is not listed. What should I send?
Send a photo of the mating part, any name or markings on it and the circuit voltage and current. The sales team can tell you whether a listed family fits or whether it needs a drawing.