The Multi-interface Integrated Equipment Pigtail is a composite harness with a circular flange mounting base that splits into RJ45, terminal block, aviation plug and PH or XH branches.

Voltage
To be confirmed
Current
To be confirmed
Wire gauge
To be confirmed
Temperature
To be confirmed
Protection
To be confirmed

Request a quote for this model

Multi-interface Integrated Equipment Pigtail
Multi-interface Integrated Equipment Pigtail view 2
Multi-interface Integrated Equipment Pigtail view 3

Specification

Flange Disc BaseSupports locked panel mounting and integrated cable routing for equipment, delivering a neat and aesthetic appearance.
Integrated Multi-Interface DesignEnables synchronous output of network, power and multi-channel signals, eliminating the need for wiring numerous separate cables.
Built-in Anti-Interference Magnetic RingsReduce electromagnetic interference to ensure long-term stable transmission of network and signals.
Marked Branch Cables for IdentificationEach cable is printed with identification marks to avoid wrong connections during on-site maintenance and wiring.
Layered Injection MoldingReinforced cable split sections resist cracking and wire breakage under repeated bending with excellent tensile resistance.
Flexible Non-Standard CustomizationOptional RJ45 connectors, aviation plugs, terminal blocks, PH/XH terminals, with adjustable cable length and wire gauge.
Weather-Resistant Sheathed CablesInsulated and corrosion-resistant, suitable for indoor equipment and light-duty outdoor equipment applications.
Fixed StructureCircular flange mounting base
Integrated InterfacesRJ45 crystal connector, green pluggable terminal block, miniature aviation plug, multi-P plastic terminal
Anti-interference ConfigurationBuilt-in magnetic ring
ProcessReinforced injection molding for branches, printed cable marking
Applicable DevicesIndustrial smart cameras, IoT gateways, access control terminals, integrated security devices, environmental monitoring equipment
Customization ScopeAddition or removal of interface types, overall cable length, branch length, terminal model, cable shielding selection

The interface mix is set by your equipment. If you need an interface or branch marking that is not listed, send the interface list.

The interface mix is the main variable: which of RJ45, terminal block, aviation plug and PH or XH branches you need. Then confirm overall cable length, branch length, terminal model, conductor specification and whether cable shielding is wanted. No voltage, current or temperature values are stated, so ask the sales team for any you need.

Overview

This harness is an outgoing wire set for equipment housings. A flange disc base locks onto the housing panel for embedded installation, and the cable divides into independent interfaces: RJ45 network crystal connectors, green pluggable terminal blocks, waterproof aviation plugs and PH or XH terminal wires.

The specification describes network communication, power supply and switching signal transmission in one set. The main cable is a sheathed cable with multiple signal wires arranged independently and a magnetic ring anti-interference structure. Connectors are injection molded, and each branch cable is marked with printed characters for identification.

This model sits in the Energy storage & automotive line. Compare it with Integrated Network Power Y-Type Splitting Harness or Push-Pull Self-Locking Aviation Connector Harness Kit or Waterproof Plug Connecting Wire for New Energy Plug Harness.

Construction notes

Flange disc mounting baseA circular flange base supports locked panel mounting and integrated cable routing, which the specification says gives equipment a neat appearance.
Several interfaces, one setNetwork, power and multi-channel signals leave through one harness, removing the need to wire many separate cables to the equipment.
Built-in magnetic ringsAnti-interference magnetic rings are built in. The specification says they reduce electromagnetic interference to support stable network and signal transmission.
Printed branch markingsEach branch cable carries printed identification marks, which the specification says helps avoid wrong connections during on-site wiring and maintenance.
Reinforced split sectionsLayered injection molding reinforces the cable split sections. The specification describes resistance to cracking and wire breakage under repeated bending.
Add or remove branchesRJ45 connectors, aviation plugs, terminal blocks and PH or XH terminals can be added or removed to suit the equipment.

Where it is used

  • Industrial smart cameras. Industrial cameras and intelligent terminals that need network, power and signal lines leaving through one panel opening.
  • IoT gateways. IoT gateways and access control terminals where several interface types must come out of one housing.
  • Integrated security devices. All-in-one security devices that combine network, power and switching signals in a single outgoing harness.
  • Outdoor monitoring. Environmental and outdoor monitoring instruments. The specification describes the sheathed cable as suitable for indoor and light-duty outdoor equipment.

When this is not the right part

  • No electrical ratings are stated: voltage, current per branch and operating temperature are all to be confirmed with the sales team. Do not size a power branch from this page alone.
  • The specification calls the cable suitable for indoor equipment and light-duty outdoor use. Heavy outdoor exposure, and any ingress protection rating, should be confirmed before you specify it.
  • Flange dimensions and mounting hole pattern are not listed. Share your panel drawing so the sales team can confirm the fit.
  • This is a custom multi-branch harness rather than a fixed catalogue part, so the exact branch layout needs to be agreed before quoting.

Customization

The specification lists interface combinations, overall cable length, branch length, conductor specifications, terminal model and cable shielding selection as customizable. Branches such as RJ45 connectors, aviation plugs, terminal blocks and plastic terminals can be added or removed as required.

To ask for a quote, send a drawing or list showing each branch, its connector type, its length and the panel cut-out for the flange. Small trial orders are discussed, and MOQ is flexible. Non-standard harness solutions are supported.

Model FAQ

Which interfaces can this harness carry?

The specification lists RJ45 network crystal connectors, green pluggable terminal blocks, waterproof aviation plugs and PH or XH terminal wires. Branches can be added or removed to match your equipment.

How is it mounted?

A circular flange disc base locks directly onto the equipment housing panel for embedded installation. Send your panel drawing so the sales team can confirm the flange size and hole pattern.

How are branches identified?

Each branch cable is marked with printed characters. The specification says this helps with on-site wiring identification and reduces the chance of installation errors.

Is cable shielding available?

Cable shielding selection is on the customization list. The main cable also has a built-in magnetic ring. Tell us your interference concerns and the sales team can discuss the options.